Radiotherapy with Cutting Field IMRT (CFIMRT)
To achieve the dose distribution corresponding to that in IMRT using a conventional irradiation method, we propose the combination of rectangular rotation irradiation and fixed multiport irradiation (cutting field IMRT). In this site, I will demonstrate several clinical cases and these 'templates'.
No smallsegments are used for planning by CFIMRT. So this method is different from 'conventional IMRT '. <Reference>
The information provided on this 'Cutting Field IMRT' website is designed to support, not replace, the relationship that exists between a patient/site visitor and his/her physician. This site provide technical guidance for medical professionals, but you must use these information by your responsibility. Cutting Field IMRT is one of techniques for radiation therapy. This site will provide its information for medical professionals. If you are not a medical specialist, please talk with health professionals when you use the informations of this site. (Medical guidelines and medical insurance system are different by countries and districts.)
Our Website does not host any form of advertisement.
This site has been managed without obtaining the funds from any other individuals, and organizations.
Please see "about us", "mission", "privacy statement": Disclaimer
Copyright (C) Sakae Taira, All rights reserved
Head
and Neck Esophagus
Breast
Abdomen
Pelvis
Sample cases planned without MLC(Multi-Leaf Collimater) (RTP arts) ->Refer to 'Intensity modulated field' QA & QC
Cutting Field Technology Combination of Fixed port and Rotational port
PowerPoint files are stored to briefcase if you need detailed drawing images.->Yahoo BriefCase
![]()
Wole neck irradiation 'Prescribe=Delivery=50Gy version'
Whole Pelvic LN irradiation (50Gy) for Prostate cancer: CTV by RTOG
Whole Pelvic LN irradiation (50Gy) for Gynecological malignancy: CTV by RTOG
![]()
![]()
6 Ports plan (2 arc) for prostate
![]()
Whole neck 66Gy by dose painting
![]()
GIF anime about MLC and Gantry moving of DMLC-IMRT ( Conventional IMRT ).
In comparison MLC doesn't move during irradiation at each directions and no subsegments are used in CFIMRT.
'Segments' and 'Intensity Map' of IMRT: GIF animation (Segments are not used basically at CFIMRT)
What is Cutting Field IMRT (CFIMRT) Advantage of CFIMRT
Information of CRIMRT CFIMRT is easy to plan
QA and QC The contributed cases
Comparison of each irradiation method
Target movement during each IMRT sessions
How do you think these 'incidents'? : IAEA PowerPoint file (Accident report)
Please be sure to perform actual dose measurement in each irradiation fields in CFIMRT. And please be sure to perform comparison with the measurement dose and the calculation dose in RTPs.
last modification date: 2014/08/15